Products

RF Components // ENVIRONMENTAL CONDITIONS

ENVIROMENTAL CONDITIONS
( Operating Temperature and Screening Test )

Requirement of devices for operating temperature varies according to the application, operating condition , etc.

TOKYO KEIKI provides the following three grades of devices based on the operating temperature conditions to meet customer's needs.

Grade Guaranteed temparature rang
C -10 ~ +50?C
D -20 ~ +70?C
M -54 ~ +95?C

For delivering more reliable products, TOKYO KEIKI conducts the temperature cycle test and the burn-in test for each grade.

ln this manner, TOKYO KEIKI microwave devices have been shipped after rigorous quality assurance test, and furhermore the screening that conforming to MIL-STD-883C shown in the table below can be added by designating the grade "S", with which higher reliability can be assured.

No. Test MIL-STD Method Conditions
1 Internal visual check 883C 2017 Modified ?
2 Stabilization bake 883C 1008 C
(24h @150?C)
3 Thermal shock 202f 107 A
(10 Cycles -55 ~ +85?C)
4 Constant acceleration 883C 2001 A
(5000G Y1 axis only)
5 Sealing ( fine leak ) 883C 1014 A1
6 Sealing (gross leak ) 883C 1014 C
7 Burn in 883C 1015 B
(100h @+100?C)
8 External visual check 883C 2009 Modified ?